  Datasheet File OCR Text:
  technical d at asheet chrome din rail power supply 5v 7.5 w 1 phase (class ii & nec class 2) / drc - 5v10w1az all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com ( september 201 4 , rev. 0 0 ) 1 highligh ts & features ? protection class ii , d ouble isolation (no earth connection is required) ? universal ac input voltage and full power up to 55 c ? power will not de - rate for the entire input voltage range ? efficiency > 78 % @ 115vac ? nec class 2 / limited power source (lps) certified ? overvoltage / overcurrent / over temperature protections safety standards cb certified for worldwide use model number: drc -5 v10w 1az unit weight : 0. 06 kg dimensions (l x w x d): 91 x 18 x 55.6 mm general description the drc -5 v1 0w1az is part of the c hrome din rail power supply series, which is designed for use in compact cabinets for home automations and the food and beverage industry. delta?s chrome din rail power supply series offers double isolated input. thi s means that no earth connection is required thus resul ting in low leakage current. this product provides a universal input voltage range of 90- 264vac, and a wide temperature range of -2 5 c to 7 1 c. the chrome series is certified to safety standard according to iec/en/ul 60950 - 1 information technology equipment (ite) and ul 508 industrial control equipment (ice). the series is also fully compliant with rohs directive 2011/65/eu for environmental prote ction. nec class 2 and limited power source (lps) approvals are available for this product. model information chrome din rail power supply model number input v oltage range output v oltage output cur r ent drc -5 v10 w1az 90-264 v ac (12 5 - 375vdc) 5vdc 1.5 a model numbering dr c ? 5 v 10 w 1 a z din rail isolation class ii power supply output voltage output power (10w series model) single phase chrome series plastic case
technical d at asheet chrome din rail power supply 5v 7.5 w 1 phase (class ii & nec class 2) / drc - 5v10w1az all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com ( september 201 4 , rev. 0 0 ) 2 specifications input ratings / characteristics nominal input v oltage 100- 240 v ac input v oltage range 90-264 v ac nominal input f r equency 50- 60hz input f r equency range 47- 63hz nominal dc input voltage * 125 - 375vdc input cur r ent < 0.3a @ 1 15 vac, < 0.2a @ 2 3 0vac ef ficiency at 100% load > 78 % @ 1 15 vac , > 77% @ 2 3 0 vac max inrush cur r ent (cold start) < 15 a @ 115vac, < 30 a @ 230vac leakage cur r ent < 0.25 ma @ 240vac * fulfills the test conditions for this range . output ratings / characteristics nominal output voltage 5 vdc output voltage range 4 . 75-5. 25vdc ( no potentiometer ) output current 1.5 a output power 7.5 w line regulation < 1 % typ. (@ 90-2 64 vac , 100% load ) load regulation < 2 % typ. (@ 90-2 64 vac, 100% load ) residual ripple / pard (20mhz) < 50mvpp / 15 0mvpp rise time < 1 00ms @ nominal input (100% load ) start - up time < 3 , 000ms @ nominal input (100% load ) hold - up time > 1 0ms @ 115vac, > 30 ms @ 230vac (100% load ) dynamic response (overshoot & undershoot o/p voltage) 5% @ 10- 100% load start - up with capacitive loads 3 ,000f max mechanical case cover plastic dimensions (l x w x d) 91 x 18 x 55.6 mm unit weight 0. 06 kg indicator green led (dc ok) cooling system convection terminal input m4 x 2 pins (rated 300v/ 16a) output m4 x 2 pins (rated 300v/ 16a) wire input / output awg 26 - 12 mounting rail standard ts35 din rail in accordance with en 60715
technical d at asheet chrome din rail power supply 5v 7.5 w 1 phase (class ii & nec class 2) / drc - 5v10w1az all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com ( september 201 4 , rev. 0 0 ) 3 environment surrounding air temperature operating -2 5 c to + 7 1 c storage - 25c to + 85 c power de - rating > 5 5 c de - rate power by 2.5% / c operating humidity 5 to 95 % rh (non - condensing) operating altitude 0 to 2 ,000 meters shock test (operating) iec 60068 -2 - 27, half sine wave : 4g for a duration of 22ms, 3 shocks for each 3 direction s , 9 times in total vibration (operating) iec 60068 -2 - 6, sine wave : 10- 500hz @ 19.6m/s2 ( 2g peak); 10 min per cycle, 60 min for all x, y, z directions pollution degree 2 protections overvoltage < 7.25 v , selv output, latch - off mode overload / overcurrent > 1 05 % of rated load current, hiccup mode, non - latching (auto- recovery when the fault is removed) over temperature > 75 c surrounding air temperature @ 100% load, latch - off mode short circuit hiccup mode, non - latching (auto - recovery when the fault is removed) degree of protection ip 20 protection against shock class i i (no pe* connection is required) *pe: primary earth reliability data mtbf > 5 00,000 hrs. as per telcordia sr -332 i/p: 100vac, o/p: 100% load, ta: 35c expected cap life time 10 years (115vac & 230vac , 50% load @ 40c )
technical d at asheet chrome din rail power supply 5v 7.5 w 1 phase (class ii & nec class 2) / drc - 5v10w1az all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com ( september 201 4 , rev. 0 0 ) 4 safety standards / directives electrical safety tuv bauart to en 60950 - 1, ul/cul recognized to ul 60950 -1 and csa c22.2 no. 60950 -1 (file no. e 131881) , cb scheme to iec 60950- 1 , limited power source (lps) industrial control equipment ul/cul listed to ul 508 and csa c22.2 no. 107.1 -01 (file no. e3 38991 ) class 2 power supply ul/cul recognized to ul 60950 - 1, csa c22.2 no. 60950 -1 ce in conformance with emc directive 2004/108/ec and low voltage directive 2006/95/ec material and parts rohs directive 2011/65/eu compliant galvanic isolation input to output 3 .0 kvac emc emc / emissions cispr 22, en 55022, fcc title 47: class b immunity to en 55024 electrostatic discharge iec 61000 -4 -2 level 3 criteria a 1) air discharge: 8kv contact discharge: 6 kv radiated field iec 61000 -4 -3 level 2 criteria a 1) 80mhz - 1ghz, 3v/m with 1khz tone / 80% modulation electrical fast transient / burst iec 61000 -4 -4 level 3 criteria a 1) 2 kv surge iec 61000 -4 -5 level 3 criteria a 1) common mode 2) : 2kv differential mode 3) : 1kv conducted iec 61000 -4 -6 level 2 criteria a 1) 150khz - 80mhz, 10 vrms power frequency magnetic fields iec 61000 -4 -8 criteria a 1) 1a/meter voltage dips iec 61000 -4 -11 > 95% dip; 0.5 cycle (10ms) voltage fluctuation and flicker iec/en 61000 -3 -3 1) criteria a: normal performance within the specification limits 2) asymmetrical: common mode (line to earth) 3) symmetrical: differential mode (line to line)
technical d at asheet chrome din rail power supply 5v 7.5 w 1 phase (class ii & nec class 2) / drc - 5v10w1az all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com ( september 201 4 , rev. 0 0 ) 5 block diagram device description 1 ) input terminal block connector 2 ) output terminal block connector 3 ) dc ok control led (green) 4 ) universal mounting system
technical d at asheet chrome din rail power supply 5v 7.5 w 1 phase (class ii & nec class 2) / drc - 5v10w1az all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com ( september 201 4 , rev. 0 0 ) 6 dimensions l x w x d: 91 x 18 x 55.6 mm engineering data de - rating note 1 . power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in fig. 1. 2 . if the output capacity is not reduced when th e surrounding air temperature > 55 c, the device may run into over temperature protection. when activated, the output voltage will go into latch - off mode and recoverable by ac power recycle. 3 . in order for the device to function in the manner intended, it is also necessary to keep a safety distance of 25 mm with adjacent units while the device is in operation. 4 . depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! 5 . if the device has to be mounted in any other orientation, please do not hesitate to contact info@deltapsu.com for more details. fig. 1 de - rating for vertical mounting orientation > 55c de - rate power by 2.5% / c
technical d at asheet chrome din rail power supply 5v 7.5 w 1 phase (class ii & nec class 2) / drc - 5v10w1az all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com ( september 201 4 , rev. 0 0 ) 7 output d e - rating vs. i nput v oltage assembly & installation the power supply unit (psu) can be mounted on 35mm din rails in accordance with en60715. the device should be installed with input terminal block at the bottom. each device is delivered ready to install. mounting ? no output power de - rating across the entire input voltage range dismounting fig. 2.1 mounting snap on the din rail as shown in fig. 2.1: 1 . tilt the unit upwards and insert it onto the din rail. 2 . push downwards until stopped. 3 . press against the bottom front side for locking. 4 . shake the unit slightly to ensure that it is secured. fig. 2.2 dismounting to uninstall, pull or slide down the latch with screw driver as shown in fig. 2.2. then slide the power supply unit (psu) in the opposite direction, release the latch and pull out the power supply unit (psu) from the rail.
technical d at asheet chrome din rail power supply 5v 7.5 w 1 phase (class ii & nec class 2) / drc - 5v10w1az all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com ( september 201 4 , rev. 0 0 ) 8 safety instructions functions graph illustrating the start - up time, rise time, and hold- up time start - up time the time required for the output voltage to reach 90% of its set value, after the input voltage is applied. rise time the time required for the output voltage to change from 10% to 90% of its set value. hold - up time hold up time is the time when the ac input collapses and ou tput voltage retains regulation for a certain period of time. the time required for the output to reach 9 0 % of its set value, after the input voltage is removed. ? always switch mains of input power off before connecting and disconnecting the input voltage to the unit. if mains are not turned off, there is risk of explosion / severe damage. ? to guarantee sufficient convection cooling, keep a distance of 5 0mm above and below the device as w ell as a lateral distance of 25 mm to other units. ? note that the enclosure of the device can become very hot depending on the surrounding air temperature and load of the power supply. risk of burns! ? do not insert any objects into the unit. ? hazardous voltages may be present for up to 5 minutes after the input mains voltage is disconnected. do not touch the unit during this time. ? the power supplies unit should be installed in minimum ip54 rated enclosure. ? the power supplies are built in units and must b e installed in a cabinet or room (condensation free environment and indoor location) that is relatively free of conductive contaminants.
technical d at asheet chrome din rail power supply 5v 7.5 w 1 phase (class ii & nec class 2) / drc - 5v10w1az all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com ( september 201 4 , rev. 0 0 ) 9 inrush current inrush current is the peak, instan taneous, input current measured and, occurs when the input voltage is first applied. for ac input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied ac voltage. this peak value decreases exponentially during subsequent cycles of ac voltage. dynamic response the po wer supply output voltage will remains within 5% of its steady state value, when subjected to a dynamic load from 10 to 100% of its rated current. overvoltage protection the power supply?s overvoltage circuit will be activated when its internal feedback circuit fails. the output voltage shall not exceed its specifications defined on page 3 under ?protections?. overload & overcurrent protections the power supply?s overl oad (olp) and over current (ocp) protections will be activated when output current rapidly exceeds 1 05% of i o (max load). in such occurrence, once the power supply has reached its maximum power limit, the protection is activated and the power supply will g o into ?hiccup mode? (auto - recovery). the power supply will recover once the fault condition of the olp and ocp is removed and i o is back within the specifications. over temperature protection as mentioned above, the power supply also has over temperature protection (otp). in the event of a higher operating condition at 100% load, the power supply will run into otp when the operating temperature is beyond what is rec ommended in the de- rating graph . when activated, the output voltage will go into l atch - off mode until the component temperature cools down and the ac power is recycled. short circuit protection the power supply?s output olp/ocp function also provides protection against short circuits . when a short circuit is applied, the output current will operate in ?hiccup mode?, as shown in the illustration in the olp/ocp section on this page. the power supply will return to normal operation after the short circuit is removed.
technical d at asheet chrome din rail power supply 5v 7.5 w 1 phase (class ii & nec class 2) / drc - 5v10w1az all parameters are specified at 25 c ambient unless otherwise indicated. www. deltapsu .com ( september 201 4 , rev. 0 0 ) 10 others delta rohs compliant restriction of the usage of hazardous substances the european directive 2011/65/e u limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants pbb and pbde for the use in electrical and electronic equipment. rohs is the abbreviation for ?restriction of the use of certain hazardous substances in electrical and electronic equipment?. this product conforms to this standard.


▲Up To Search▲   

 
Price & Availability of DRC-5V10W1AZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X